Skip to main content

Water details

These details govern the requirements for the construction of water facilities within the City of Rochester. Details are available in DWG, DXF and PDF formats. 

NUMBER DATEDRAWING TITLE
S900-111/22/10Water Trench Pavement Reconstruction  (dwg)     (dxf)   (pdf)
S900-211/22/10Water Trench Pavement Rehabilitation  (dwg)     (dxf)     (pdf)
S900-311/22/10Water Main Crossing Below Sewer  (dwg)     (dxf)     (pdf)
S900-48/7/13Horizontal Thrust Block Domestic System (dwg)     (dxf)     (pdf)
S900-56/1/09Vertical Thrust Block Domestic System (dwg)     (dxf)     (pdf)
S900-62/19/15Disinfection Sampling Tap  (dwg)     (dxf)     (pdf)
S900-79/1/09Water Main Pipe Restraint Domestic System  (dwg)     (dxf)     (pdf)
S900-89/1/09Water Main Pipe Restraint Holly System  (dwg)     (dxf)     (pdf)
S900-98/7/13Horizontal Thrust Block Holly System  (dwg)     (dxf)     (pdf)
S900-106/1/09Vertical Thrust Block Holly System  (dwg)     (dxf)     (pdf)
S900-113/23/11Replacement of 4 Inch and Larger Water Service on New Water Main     (dwg)     (dxf)     (pdf)
S900-124/29/11Water Service Tap Excavation     (dwg)     (dxf)     (pdf)
S901-86/1/09Plastic Water Main Tracer Wire Installation  (dwg)     (dxf)     (pdf)
S901-94/19/18Plastic Water Service Tracer Wire Installation  (pdf)
S901-102/19/15Plastic Water Main Tracer Wire End to End Splice Connection  (dwg)     (dxf)     (pdf)
S901-116/1/09Plastic Water Service Tracer Wire Tap Splice Connection  (dwg)     (dxf)     (pdf)
S901-1212/15/10Impervious Clay Water Main Trench Plug  (dwg)     (dxf)     (pdf)
R905-16/1/09Cutting-In Valve Installation  (dwg)     (dxf)     (pdf)
S909-16/17/21Water Valve Box Adjustment or Replacement  (pdf)
S909-2N/AConcrete Collar for Valve Box Within Roadway (Detail on Public Works Construction Details Page)
S909-3N/AAsphalt Restoration for Valve Box Within Roadway (Detail on Public Works Construction Details Page)
S909-4  N/ARound Concrete Collar for Valve Box Within Roadway (Detail on Public Works Construction Details Page)
S909-5  N/AConcrete Collar for Multiple Valve Boxes Within Roadway (Detail on Public Works Construction Details Page)
S911-12/19/15Pitometer Tap  (dwg)     (dxf)     (pdf)
R913-16/1/09Water Service Pipe 2 Inch and Smaller  (dwg)     (dxf)     (pdf)
R913-26/1/09Existing Copper Water Service Pipe Extension 2 Inch and Smaller  (dwg)     (dxf)     (pdf)
R913-311/24/20Water Service Card  (pdf)
S916-16/1/09Bypass Pipe Crossing at Driveway, Sidewalk and Street  (dwg)     (dxf)     (pdf)
S916-211/22/10Bypass Pipe at Sidewalk Access Ramp  (dwg)     (dxf)     (pdf)
R917-11/25/17Hydrant and Valve with New Branch  (dwg)     (dxf)     (pdf)
R917-21/25/17Hydrant at Existing Branch  (dwg)     (dxf)     (pdf)
S920-29/16/13Water Meter Vault for Domestic Meter 3 Inch to 10 Inch  (dwg)     (dxf)     (pdf)
S920-39/16/13Water Meter Vault Dimensions and Notes  (dwg)     (dxf)     (pdf)
S922-12/25/14Permanent Blow-Off Assembly  (dwg)    (dxf)   (pdf)
S924-15/10/11Water Meter Pit 1 Inch and Smaller in Lawn Area  (dwg)     (dxf)     (pdf)
S924-25/10/11Water Meter Pit 1-1/2 Inch and 2 Inch in Lawn Area  (dwg)     (dxf)     (pdf)
S925-15/11/11Yard Hydrant     (dwg)     (dxf)     (pdf) 
S962-19/16/13Joint Bond for Metallic Water Main Pipe/Fitting  (dwg)     (dxf)     (pdf)
S966-112/28/10Anode at New Ductile Iron Water Main or Ductile Iron Fitting on New Plastic Water Main  (dwg)     (dxf)     (pdf)
S966-212/28/10Thermite Weld Details  (dwg)     (dxf)     (pdf)
S966-312/28/10Anode at New Copper Water Service on Plastic Water Main  (dwg)     (dxf)     (pdf)
S966-412/28/10Anode at New Water Service on Existing Cast/Ductile Iron Water Main  (dwg)     (dxf)     (pdf)
S966-512/28/10Anode at Existing Ductile/Cast Iron Pipe Joint (Reconstruction)  (dwg)     (dxf)     (pdf)
S966-612/28/10Anode at Existing Ductile/Cast Iron Pipe Joint (Rehabilitation)  (dwg)     (dxf)     (pdf)
S966-71/05/12Anode at Insertion Sleeve and Cut-In Tee on Existing Iron Pipe    (dwg)    (dxf)    (pdf)
S966-811/03/14Anode at Existing Ductile/Cast Iron Pipe Joint (Double Anodes)   (dwg)     (dxf)    (pdf)   
S966-97/7/16Anode at Tapping Sleeve and Valve on Existing Cast/Ductile Iron Water Main (dwg)   (dxf)   (pdf)
S968-110/24/13Cathodic Protection Test Station for Metallic Water Pipe or Fitting (1 of 2) (dwg)     (dxf)     (pdf)
S968-210/24/13Cathodic Protection Test Station for Metallic Water Pipe or Fitting (2 of 2)  (dwg)     (dxf)     (pdf)
S970-17/13/11New Water Service 2 Inch and Smaller    (dwg)    (dxf)    (pdf)
S970-29/16/13Indoor Installation of Water Meter 1 Inch and Smaller    (dwg)    (dxf)    (pdf)
S970-39/16/13Indoor Installation of Water Meter 1-1/2 Inch and 2 Inch    (dwg)    (dxf)    (pdf)
S970-48/8/11New Water Service 4 Inch and Larger on Existing Water Main    (dwg)    (dxf)    (pdf)
S970-58/11/11New Water Service 4 Inch and Larger on Existing Water Main Notes    (dwg)    (dxf)    (pdf)
S970-68/8/11Typical Indoor Installation of Domestic Water Meter 3 Inch to 10 Inch    (dwg)    (dxf)    (pdf)
S970-78/27/13Typical Water Meter Installation for Holly Fire Service 4 Inch and Larger    (dwg)    (dxf)    (pdf)
S970-88/8/11Typical Water Meter Installation for Domestic Fire Service 4 Inch and Larger    (dwg)    (dxf)    (pdf)
S970-93/8/12Typical Combination Fire and Domestic Service    (dwg)    (dxf)    (pdf)
S971-16/21/11Reduced Pressure Zone (RPZ) Backflow Prevention Device 2 Inch and Smaller    (dwg)    (dxf)    (pdf)
S971-26/21/11Reduced Pressure Zone (RPZ) Backflow Prevention Device 2-1/2 Inch and Larger    (dwg)    (dxf)    (pdf)
S971-36/21/11Reduced Pressure Zone (RPZ) Air Gap and Drain Line Installations    (dwg)    (dxf)    (pdf)

When working with the dwg and dxf formatted files in AutoCAD or Microstation, it may be necessary to reformat the text font for notes to the original text font (Calibri true type regular font, 1.80 height).

Additional Water Facility Resources

Check out the City's water specifications.